Current Date : 05/26/13 Current Time : 00:30 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 Logger Id : CM Logger Name : CLEMMONS MIDDLE Interval : 001H Param : OZONE O38HR PM25MASS 24HRM OPERMODE %LOAD FRM1HR FRM24HR STMP Units : PPB PPB UG/M3 UG/M3 4-OK % UG/M3 UG/M3 DEGC Hour -------------------------------------------------------------------------------------------------------------- 00 31.3 40.3C 10.1 4.3 4.00 24 10.1 4.3 19.8 01 26.6 38.0C 9.9 4.7 4.00 24 9.8 4.7 19.8 02 18.9 34.6C 1.3 4.7 4.00 24 1.0 4.7 20.2 03 13.4 31.0C 6.5 4.7 4.00 24 6.3 4.7 20.6 04 11.0 27.2C 4.4 4.6 4.00 25 4.2 4.6 20.7 05 7.7 23.4C 8.2 4.7 4.00 24 8.1 4.7 20.8 06 13.5 19.7C 10.9 4.8 4.00 24 10.8 4.8 20.2 07 37.2 20.0 .0 4.5 4.00 24 -.3 4.5 20.8 08 42.7 21.4 3.5 4.6 4.00 23 3.3 4.6 22.4 09 43.7 23.5 3.4 4.8 4.00 23 3.2 4.8 24.2 10 44.5 26.7 5.3 4.9 4.00 23 5.1 4.9 26.3 11 46.0 30.8 2.6 5.0 4.00 23 2.3 5.0 27.2 12 47.2 35.3 2.3 5.0 4.00 23 2.1 5.0 27.7 13 48.0 40.3 2.4 4.9 4.00 23 2.2 4.9 28.3 14 48.4 44.7 5.1 5.1 4.00 23 4.9 5.1 28.5 15 48.7 46.1 5.6 5.2 4.00 23 5.4 5.2 28.5 16 47.6 46.7 4.9 5.3 4.00 23 4.7 5.3 28.1 17 45.7 47.0 2.5 5.3 4.00 23 2.3 5.3 27.3 18 44.6 47.0 1.5 5.2 4.00 23 1.2 5.2 26.3 19 39.3 46.2 4.4 5.1 4.00 23 4.2 5.1 25.7 20 32.2 44.3 6.1 5.1 4.00 24 5.9 5.1 25.2 21 36.2 42.8 6.8 5.1 4.00 24 6.7 5.1 24.3 22 39.1C 41.7C 8.2 5.1 4.00 24 8.0 5.1 23.5 23 30.6C 39.4C 7.9 5.2 4.00 24 7.8 5.2 23.2 Max : 48.7 47.0 10.9 5.3 4.00 25 10.8 5.3 28.5 Min : 7.7 19.7 .0 4.3 4.00 23 -.3 4.3 19.8 Mean : 35.1 35.7 5.1 4.9 4.00 23 4.9 4.9 24.1 Hours : 24 24 24 24 24 24 24 24 24 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Current Date : 05/26/13 Current Time : 00:30 Calibration Report CENTRAL POLLING COMPUTER Sequence Phase Param Start End Calibration Expected Drift Date Id Name Name Name Time Time Value Value (E.U.s) ------------------------------------------------------------------------------- 05/25/13 CM OZONE3PT LVL_ZERO OZONE 22:46 22:53 .7 .0 .700 LVL_SPAN OZONE 22:46 23:04 224.0 225.0 -.44 LVL_PREC OZONE 22:46 23:12 69.1 70.0 -1.28 ------------------------------------------------------------------------------- Current Date : 05/26/13 Current Time : 00:30 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 Logger Id : HA Logger Name : HATTIE AVENUE Interval : 001H Param : SO2 NO NO2 NOX OZONE STMP O38HR TEMP DEWPT RH Units : PPB PPM PPM PPM PPB DEGC PPB DEGC DEGC % Hour -------------------------------------------------------------------------------------------------------------- 00 .0 .000 .003 .004 35.9 25.0 42.6C 9.41 2.30 64.46 01 -.1 .000 .004 .005 34.0 25.0 41.0C 8.62 2.26 68.20 02 -.1 .000 .009 .011 17.4 25.0 37.3C 7.74 3.06 76.58 03 -.1 .000 .006 .008 19.4 25.3 34.0C 6.70 2.99 81.42 04 -.1 .000 .007 .008 13.3 25.3 30.7C 6.09 3.49 86.98 05 -.1 .001 .006 .008 20.1 25.4 27.9C 6.50 2.82 81.63 06 .0 .001 .002 .004 36.5 25.5 27.1C 10.67 1.84 55.86 07 .0 .001 .001 .003 42.0 25.9 27.3 14.18 2.21 40.19 08 .0 .000 .001 .002 43.3 26.7 28.3 15.70 3.31 38.07 09 .0 .000 .000 .002 46.0 27.2 29.8 17.84 4.32 32.41 10 .0 .000 .000 .002 46.9 25.6 33.4 19.89 6.02 30.65 11 .0 .000 .000 .002 48.2 24.5 37.1 20.94 7.21 31.34 12 .0 .000 .000 .002 49.3 24.1 41.6 22.35 7.86 27.59 13 .0 .000 .000 .001 50.9 23.8 45.4 23.25 8.67 27.12 14 .0 .000 .000 .001 52.0 23.7 47.3 24.79 10.08 26.41 15 .0 .000 .000 .002 51.7 23.5 48.5 24.94 10.28 26.68 16 .0 .000 .000 .002 49.6 23.1 49.3 24.69 10.08 26.91 17 .0 .000 .001 .002 50.4 23.1 49.9 23.58 8.72 25.66 18 .0 .000 .002 .003 49.3 24.4 50.2 21.08 6.60 27.56 19 .0 .000 .006 .008 42.4 25.7 49.5 18.75 4.94 30.92 20 .0 .000C .006C .007C 42.1 25.7 48.6 16.39 3.03 33.19 21 -.1C .000C .004C .006C 40.9 25.1 47.3 14.49 2.59 40.49 22 .0C .000 .004 .005 37.7C 24.2 45.5C 13.37 2.47 45.53 23 .0 .000 .005 .006 32.2C 24.7 43.1C 12.42 3.03 53.08 Max : .0 .001 .009 .011 52.0 27.2 50.2 24.94 10.28 86.98 Min : -.1 .000 .000 .001 13.3 23.1 27.1 6.09 1.84 25.66 Mean : .0 .000 .002 .004 39.6 24.8 40.1 16.01 5.00 44.95 Hours : 24 24 24 24 24 24 24 24 24 24 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Page : 2 of 2 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 (continued) Logger Id : HA Logger Name : HATTIE AVENUE Interval : 001H Param : PRESSURE WS WD NO2PREC GRIM25 GRIM10 GRIMCRS Units : MMHG MPH DEG PPB UG/M3 UG/M3 Hour -------------------------------------------------------------------------------------------------------------- 00 726.7 .5 74 .080 5.8 8.9 3.0 01 726.8 .4 249 .080 5.7 8.5 2.8 02 727.0 .8 204 .080 6.9 9.1 2.2 03 726.9 .4 168 .080 6.7 8.7 2.0 04 727.2 .5 149 .080 6.9 9.0 2.0 05 727.2 1.1 346 .080 6.0 7.6 1.6 06 727.6 1.9 345 .080 4.6 6.7 2.1 07 728.0 1.9 21 .080 4.4 6.3 1.8 08 728.4 2.5 258 .080 4.9 7.6 2.6 09 728.2 2.7 281 .080 4.1 6.2 2.1 10 728.1 3.1 271 .080 3.3 5.5 2.2 11 727.5 2.7 246 .080 3.2 5.4 2.2 12 726.9 2.7 252 .080 2.5 4.5 2.0 13 726.2 2.5 257 .080 2.5 4.3 1.8 14 725.7 2.5 248 .080 2.4 4.2 1.8 15 725.3 2.3 248 .080 2.4 4.6 2.1 16 725.1 2.3 262 .080 2.3 4.6 2.3 17 725.1 2.4 284 .080 2.4 4.5 2.1 18 725.3 1.5 246 .080 3.0 6.8 3.8 19 725.6 .7 17 .080 3.9 9.8 5.9 20 726.0 1.0 26 .080 3.6 6.8 3.2 21 726.3 1.0 22 .074C 3.9 6.5 2.5 22 726.5 .9 55 .072 4.3 6.8 2.5 23 726.7 .6 53 .072 4.8 7.0 2.2 Max : 728.4 3.1 346 .080 6.9 9.8 5.9 Min : 725.1 .4 17 .072 2.3 4.2 1.6 Mean : 726.6 1.6 284 .079 4.1 6.6 2.4 Hours : 24 24 24 24 24 24 24 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Current Date : 05/26/13 Current Time : 00:30 Calibration Report CENTRAL POLLING COMPUTER Sequence Phase Param Start End Calibration Expected Drift Date Id Name Name Name Time Time Value Value (E.U.s) ------------------------------------------------------------------------------- 05/25/13 HA NO2DIFF PRECDIFF NO2PREC NOXAUTO NOPREC NO NOX GPTZ NO GPTPREC NO NO2 NOZERO NO2 NO NOX NOSPAN NOX NO2 NO OZONE3PT LVL_ZERO OZONE LVL_SPAN OZONE LVL_PREC OZONE SO2AUTO ZERO SO2 SPAN SO2 PREC SO2 ------------------------------------------------------------------------------- Current Date : 05/26/13 Current Time : 00:30 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 Logger Id : HB Logger Name : HATTIE AVENUE "B" Interval : 001H Param : PM25MASS 24HRM MFLOW25 %LOAD PM10MASS 24HRPM10 MFLOW10 LOAD10 REFV STMP Units : UG/M3 UG/M3 L/M % UG/M3 UG/M3 L/M % MV DEGC Hour -------------------------------------------------------------------------------------------------------------- 00 7.7 5.0B 1.99 21 11.0 10.3B 2.99 40 800.8 26.1 01 6.7 5.2B 1.99 21 10.3 10.3B 2.99 41 800.8 25.5 02 8.4 5.5B 1.99 21 11.8 10.4B 2.99 41 800.8 25.5 03 8.1 5.5B 1.99 21 9.7 10.3B 2.99 41 800.8 25.6 04 7.4 5.5B 1.99 22 9.6 10.1B 2.99 41 800.8 25.4 05 6.0 5.4B 1.99 21 8.4 9.9B 2.99 41 800.8 25.4 06 3.5 5.0B 1.99 21 3.4 9.2B 2.99 40 800.8 25.6 07 6.9 5.0B 1.99 21 13.8 9.4B 2.99 39 800.8 27.5 08 5.0 5.3B 1.99 20 7.3 9.7B 2.99 39 800.8 26.5 09 5.2 5.4B 1.99 20 7.4 9.8B 2.99 38 800.8 26.4 10 4.8 5.4B 1.99 20 7.1 9.6B 2.99 38 800.8 26.3 11 4.8 5.3 1.99 20 8.3 9.6 2.99 38 800.8 25.4 12 1.0 5.3 1.99 20 5.0 9.4 2.99 38 800.8 25.6 13 4.0 5.3 1.99 20 9.0 9.5 2.99 38 800.8 25.3 14 4.6 5.4 1.99 20 6.6 9.6 2.99 37 800.8 24.8 15 4.1 5.5 1.99 20 7.4 9.5 2.99 37 800.8 24.7 16 3.9 5.6 1.99 20 6.1 9.4 2.99 37 800.8 24.5 17 1.4 5.6 1.99 20 2.8 9.2 2.99 38 800.8 25.2 18 5.3 5.6 1.99 20 12.9 9.1 2.99 38 800.8 25.6 19 5.1 5.6 1.99 20 8.3 9.0 2.99 39 800.8 26.4 20 6.2 5.5 1.99 21 9.5 8.7 2.99 39 800.8 26.9 21 6.2 5.4 1.99 21 8.6 8.5 2.99 40 800.8 26.7 22 7.0 5.5 1.99 21 9.6 8.6 2.99 40 800.8 27.4 23 8.9 5.5 1.99 21 12.1 8.6 2.99 40 800.8 27.4 Max : 8.9 5.6 1.99 22 13.8 10.4 2.99 41 800.8 27.5 Min : 1.0 5.0 1.99 20 2.8 8.5 2.99 37 800.8 24.5 Mean : 5.5 5.3 1.99 20 8.5 9.4 2.99 39 800.8 25.9 Hours : 24 24 24 24 24 24 24 24 24 24 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Page : 2 of 2 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 (continued) Logger Id : HB Logger Name : HATTIE AVENUE "B" Interval : 001H Param : PM10STP PMRATIO FRM1HR FRM24HR PMCOARSE Units : UG/M3 UG/M3 UG/M3 UG/M3 Hour -------------------------------------------------------------------------------------------------------------- 00 10.9 .694 6.8 4.1B 3.3 01 10.2 .648 5.8 4.4B 3.6 02 11.7 .711 7.6 4.6B 3.4 03 9.6 .831 7.2 4.7B 1.6 04 9.5 .773 6.6 4.6B 2.1 05 8.3 .718 5.1 4.5B 2.3 06 3.4 1.030 2.6 4.1B -.1 07 13.7 .499 6.0 4.2B 6.9 08 7.2 .695 4.2 4.4B 2.2 09 7.3 .709 4.4 4.5B 2.1 10 7.0 .676 3.9 4.5B 2.3 11 8.2 .584 4.0 4.5 3.4 12 5.0 .205 .1 4.4 4.0 13 8.9 .445 3.1 4.5 4.9 14 6.5 .697 3.7 4.6 2.0 15 7.4 .557 3.2 4.7 3.3 16 6.0 .637 3.0 4.8 2.2 17 2.8 .519 .5 4.7 1.3 18 12.8 .412 4.4 4.8 7.6 19 8.2 .620 4.3 4.7 3.1 20 9.4 .660 5.4 4.6 3.2 21 8.6 .715 5.3 4.5 2.4 22 9.5 .729 6.2 4.6 2.6 23 12.0 .737 8.1 4.7 3.1 Max : 13.7 1.030 8.1 4.8 7.6 Min : 2.8 .205 .1 4.1 -.1 Mean : 8.5 .645 4.6 4.5 3.0 Hours : 24 24 24 24 24 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Current Date : 05/26/13 Current Time : 00:30 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 Logger Id : PC Logger Name : PETERS CREEK Interval : 001H Param : CO STMP REFV CO8HR Units : PPM DEGC MV PPM Hour -------------------------------------------------------------------------------------------------------------- 00 .3 23.9 799.0 .3C 01 .3 23.2 799.0 .3C 02 .3 23.9 799.0 .3C 03 .3 23.2 799.0 .3C 04 .3 24.1 799.0 .3C 05 .4 23.4 799.0 .3 06 .4 23.2 799.0 .3 07 .2 23.0 799.0 .3 08 .2 25.1 799.0 .3 09 .2 24.9 799.0 .3 10 .2 25.0 799.0 .3 11 .3 24.7 799.0 .3 12 .2 24.9 799.0 .3 13 .3 24.9 799.0 .3 14 .3 25.2 799.0 .2 15 .3 25.3 799.0 .2 16 .2 24.9 799.0 .2 17 .2 25.0 799.0 .2 18 .2 23.9 799.0 .2 19 .3 24.4 799.0 .2 20 .3C 24.2 799.0 .3C 21 .3C 23.8 799.0 .3C 22 23 Max : .4 25.3 799.0 .3 Min : .2 23.0 799.0 .2 Mean : .2 24.2 799.0 .2 Hours : 22 22 22 22 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Current Date : 05/26/13 Current Time : 00:30 Calibration Report CENTRAL POLLING COMPUTER Sequence Phase Param Start End Calibration Expected Drift Date Id Name Name Name Time Time Value Value (%Span) ------------------------------------------------------------------------------- 05/25/13 PC CO_Z/S/P ZERO CO 20:46 20:54 .1 .0 SPAN CO 20:46 21:02 22.4 22.5 -.44 PREC CO 20:46 21:10 8.9 9.0 -1.11 ------------------------------------------------------------------------------- Current Date : 05/26/13 Current Time : 00:30 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 Logger Id : SC Logger Name : SHILOH CHURCH Interval : 001H Param : OZONE O38HR O3CAL STMP K1ZEROAN K3SPANAN K5PRECAN Units : PPB PPB PPB DEGC PPB PPB PPB Hour -------------------------------------------------------------------------------------------------------------- 00 33.3 40.8C .0 23.6 .8 224.6 69.5 01 28.7 38.8C .0 23.4 .8 224.6 69.5 02 26.8 36.6C .0 23.4 .8 224.6 69.5 03 25.3 34.1C .0 23.6 .8 224.6 69.5 04 22.0 31.6C .0 23.4 .8 224.6 69.5 05 27.0 30.3C .0 23.5 .8 224.6 69.5 06 27.2 28.6C .0 23.3 .8 224.6 69.5 07 32.4 27.8 .0 22.9 .8 224.6 69.5 08 38.7 28.5 .0 22.0 .8 224.6 69.5 09 42.2 30.2 .0 23.4 .8 224.6 69.5 10 43.7 32.3 .0 25.0 .8 224.6 69.5 11 44.1 34.7 .0 26.0 .8 224.6 69.5 12 45.2 37.6 .0 27.0 .8 224.6 69.5 13 45.8 39.9 .0 26.5 .8 224.6 69.5 14 45.0 42.1 .0 26.1 .8 224.6 69.5 15 45.6 43.8 .0 26.2 .8 224.6 69.5 16 47.5 44.9 .0 26.5 .8 224.6 69.5 17 48.0 45.6 .0 26.8 .8 224.6 69.5 18 40.8 45.3 .0 26.7 .8 224.6 69.5 19 37.8 44.5 .0 23.7 .8 224.6 69.5 20 34.3 43.1 .0 22.9 .8 224.6 69.5 21 33.6 41.6 .0 22.7 .8 224.6 69.5 22 32.0C 40.0C .0C 23.8 .8 224.6 69.5 23 Max : 48.0 45.6 .0 27.0 .8 224.6 69.5 Min : 22.0 27.8 .0 22.0 .8 224.6 69.5 Mean : 36.8 37.5 .0 24.4 .8 224.6 69.5 Hours : 23 23 23 23 23 23 23 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Current Date : 05/26/13 Current Time : 00:30 Calibration Report CENTRAL POLLING COMPUTER Sequence Phase Param Start End Calibration Expected Drift Date Id Name Name Name Time Time Value Value (E.U.s) ------------------------------------------------------------------------------- 05/25/13 SC CALDIFF ZERODIFF K1ZEROAN SPANDIFF K3SPANAN PRECDIFF K5PRECAN OZONE3PT LVL_ZERO OZONE O3CAL LVL_SPAN OZONE O3CAL LVL_PREC OZONE O3CAL ------------------------------------------------------------------------------- Current Date : 05/26/13 Current Time : 00:30 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 Logger Id : UC Logger Name : UNION CROSS Interval : 001H Param : OZONE O38HR STMP TEMP DEWPT WS WD RH PRESSURE TEMPF Units : PPB PPB DEGC DEGC DEGC MPH DEG % MMHG DEGF Hour -------------------------------------------------------------------------------------------------------------- 00 37.7 42.5C 23.6 10.3 2.2 4.3 334 59.4 744.5 50.7 01 29.9 40.7C 25.0 8.2 3.2 2.3 322 75.2 744.1 46.7 02 27.0 38.5C 25.0 7.0 3.3 1.2 355 81.7 744.9 44.6 03 27.1 36.0C 24.9 6.6 3.1 1.6 321 82.7 744.4 43.9 04 15.2 32.4C 24.4 5.6 3.7 2.6 304 90.5 744.5 42.2 05 25.7 30.4C 24.3 7.8 2.0 5.9 353 71.0 744.6 46.1 06 33.8 29.4C 23.7 10.1 2.3 6.2 331 60.8 746.1 50.2 07 39.4 29.5 21.8 11.9 2.0 7.6 330 50.7 746.8 53.4 08 42.1 30.0 21.9 13.6 2.4 9.0 317 43.8 747.0 56.5 09 44.8 31.9 22.7 15.5 2.8 9.8 310 36.3 747.2 60.0 10 45.0 34.1 23.6 17.0 4.3 9.3 298 36.8 747.2 62.6 11 46.3 36.5 24.6 18.2 5.5 8.9 302 36.3 746.6 64.8 12 47.5 40.6 25.7 19.2 6.5 6.4 289 36.1 746.0 66.7 13 48.3 43.4 27.0 20.4 7.1 7.5 296 33.7 745.3 68.7 14 48.7 45.3 23.9 21.4 7.9 8.1 299 32.2 744.8 70.6 15 48.9 46.4 24.2 22.2 8.3 10.5 310 30.1 744.4 72.1 16 48.2 47.2 24.4 22.6 8.7 10.0 305 30.4 744.1 72.7 17 48.1 47.6 24.1 22.8 8.5 10.9 315 28.6 744.0 73.1 18 48.5 48.1 24.0 21.8 7.0 8.1 315 26.0 744.2 71.2 19 44.4 47.8 25.5 19.5 5.6 7.1 351 30.7 744.3 67.1 20 39.1 46.8 24.9 17.4 4.5 7.3 6 35.2 743.9 63.4 21 38.2 45.5 23.6 15.3 3.7 5.9 7 41.7 743.9 59.6 22 32.6C 43.5C 22.3 13.4 3.5 6.0 23 50.0 744.4 56.2 23 32.5C 41.5C 21.6 12.8 3.3 7.0 18 52.5 745.3 55.1 Max : 48.9 48.1 27.0 22.8 8.7 10.9 355 90.5 747.2 73.1 Min : 15.2 29.4 21.6 5.6 2.0 1.2 6 26.0 743.9 42.2 Mean : 39.1 39.8 24.0 15.0 4.6 6.8 326 48.0 745.1 59.0 Hours : 24 24 24 24 24 24 24 24 24 24 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Page : 2 of 2 Daily Hourly and Calibration Report - Hourly Averages CENTRAL POLLING COMPUTER 05/25/13 (continued) Logger Id : UC Logger Name : UNION CROSS Interval : 001H Param : DEWPTF K1ZEROAN K3SPANAN K5PRECAN Units : DEGF PPB PPB PPB Hour -------------------------------------------------------------------------------------------------------------- 00 36.1 -.6 222.6 69.6 01 37.8 -.6 222.6 69.6 02 38.1 -.6 222.6 69.6 03 37.6 -.6 222.6 69.6 04 38.8 -.6 222.6 69.6 05 35.7 -.6 222.6 69.6 06 36.2 -.6 222.6 69.6 07 35.7 -.6 222.6 69.6 08 36.3 -.6 222.6 69.6 09 37.1 -.6 222.6 69.6 10 39.8 -.6 222.6 69.6 11 41.9 -.6 222.6 69.6 12 43.7 -.6 222.6 69.6 13 44.9 -.6 222.6 69.6 14 46.2 -.6 222.6 69.6 15 46.9 -.6 222.6 69.6 16 47.6 -.6 222.6 69.6 17 47.4 -.6 222.6 69.6 18 44.6 -.6 222.6 69.6 19 42.2 -.6 222.6 69.6 20 40.1 -.6 222.6 69.6 21 38.6 -.6 222.6 69.6 22 38.3 -.6 222.6 69.6 23 38.1 -.4C 222.5C 69.2C Max : 47.6 -.4 222.6 69.6 Min : 35.7 -.6 222.5 69.2 Mean : 40.4 -.5 222.5 69.5 Hours : 24 24 24 24 Data : '<' - Less than ##% Data, 'P' - Power Fail, 'D' - Disabled, 'T' - Out-of-Control, 'F' - Boiler Off-Line, Flags : 'B' - Bad Status, 'C' - Calibration, 'M' - Maintenance, 'O' - Analog Overrange, 'U' - Analog Underrange, 'A' - Arithmetic Error, '+' - Maximum, '-' - Minimum, 'R' - Rate of Change, 'H' - High-High Alarm, 'L' - Low-Low Alarm, 'h' - High Alarm, 'l' - Low Alarm, 'J' - High Rate of Change, 'j' - Low Rate of Change, 'V' - DIS #1 Obs, 'W' - DIS #2 Obs, 'X' - DIS #3 Obs, 'Y' - DIS #4 Obs, 'Z' - DIS #5 Obs, 'f' - Floor Exceeded, 'c' - Ceiling Exc. Current Date : 05/26/13 Current Time : 00:30 Calibration Report CENTRAL POLLING COMPUTER Sequence Phase Param Start End Calibration Expected Drift Date Id Name Name Name Time Time Value Value (E.U.s) ------------------------------------------------------------------------------- 05/25/13 UC CALDIFF ZERODIFF K1ZEROAN 23:55 23:55 -.4 .0 -.400 SPANDIFF K3SPANAN 23:55 23:55 222.5 225.0 -1.11 PRECDIFF K5PRECAN 23:55 23:55 69.1 69.3 -.28 OZONE3PT LVL_ZERO OZONE 22:46 22:53 -.4 .0 LVL_SPAN OZONE 22:46 23:04 222.5 225.0 -1.11 LVL_PREC OZONE 22:46 23:12 69.1 70.0 -1.28 -------------------------------------------------------------------------------